Skip to content
IoT Security Lab
EU NIS2 & IEC 62443 // INDEPENDENT OT REVIEW

Industrial OT, CNC/PLC & EU NIS2 Readiness Audits

Hardware-aware vulnerability assessment, segmentation review, and firmware analysis for CNC, PLC, SCADA, and factory IoT environments.

NON-INTRUSIVE BY DEFAULTVENDOR-NEUTRALENGINEERING-LED
IEC 62443 ZONES & CONDUITSSR CONTROLS MAPPED
IEC 62443 OT zones and inspected security conduitsCloud telemetry using MQTT on port 8883 connects through controlled paths to Level 3 operations using OPC UA on port 4840, an industrial firewall and DMZ, and Level 0–1 CNC and PLC systems using Modbus on port 502 and S7comm on port 102.ARCHITECTURE REFERENCE // BIDIRECTIONAL FLOWS REQUIRE POLICYCloud TelemetryMQTT 8883 // SR 1.13 + SR 4.3EXTERNAL ZONEAUTHENTICATELevel 3: OperationsOPC UA 4840 // SR 2.1 AUTHORIZATIONOPERATIONS ZONEINSPECTIndustrial Firewall / DMZSR 5.1 SEGMENTATION // SR 5.2 BOUNDARY PROTECTIONJUMP HOST // MFA // SESSION LOGGING // DENIED-PATH TESTPERMIT LISTLevel 0–1: CNC / PLC FloorModbus 502, S7comm 102 // EtherNet/IP 44818CONTROL ZONE // SR 3.1 COMMUNICATION INTEGRITYIEC 62443-3-3 REFERENCE // VERIFY CONFIGURATION IN A SAFE TEST WINDOW
AUDIT METHODOLOGY // THREE-PHASE EXECUTION

A Systematic OT & NIS2 Readiness Roadmap

Designed around operational continuity. Passive observation comes first; active diagnostics are agreed, bounded, and scheduled with your engineering team.

01
PHASE 01 // DISCOVERY

Asset & Firmware Discovery

Build a defensible inventory of industrial assets, connectivity, firmware versions, remote access paths, and dependencies without disrupting production.

  • Passive network observation
  • Firmware and SBOM review
  • Architecture and data-flow mapping
02
PHASE 02 // VERIFICATION

Vulnerability & NIS2 Gap Analysis

Test prioritized attack paths and map technical evidence to NIS2 risk-management duties and relevant IEC 62443 security controls.

  • Controlled protocol testing
  • Zone and conduit review
  • Identity and update-path analysis
03
PHASE 03 // REMEDIATION

Roadmap & Evidence Pack

Turn findings into achievable engineering actions with clear ownership, verification steps, and operational constraints.

  • Risk-ranked remediation plan
  • Incident workflow review
  • Re-test criteria and audit evidence
SECURITY MATURITY // BEFORE & AFTER

From Unverified OT to an Evidence-Led Environment

The objective is not a checkbox. It is a defensible technical posture with clear controls, observable boundaries, and maintainable improvements.

Network segmentation

EXPOSURE

Flat networks allow a compromised workstation to reach controllers and field devices.

VERIFIABLE CONTROL

Defined zones and conduits limit access to required systems, protocols, and commands.

Firmware integrity

EXPOSURE

Unsigned images and exposed debug interfaces make unauthorized modification difficult to detect.

VERIFIABLE CONTROL

Verified boot, controlled debug access, and traceable firmware provenance support integrity.

Incident detection

EXPOSURE

Limited telemetry leaves abnormal commands and configuration changes without investigation trails.

VERIFIABLE CONTROL

Monitored control boundaries and retained events support timely triage and reporting.

Governance & NIS2

EXPOSURE

Unassigned controls and informal procedures prevent consistent evidence and executive oversight.

VERIFIABLE CONTROL

Named owners, reviewed procedures, and testable evidence connect operations to governance.

Software supply chain

EXPOSURE

Unknown third-party components obscure exposure to newly disclosed vulnerabilities.

VERIFIABLE CONTROL

Maintained SBOMs and vulnerability triage link components to remediation decisions.

SELF-ASSESSMENT // SIX TECHNICAL CONTROLS

NIS2 & OT Readiness — 6-Question Risk Check

Answer for the current production state, not the target design. Each Yes confirms one control; an unanswered question is not counted as verified.

UNSCORED: 0/6

ANSWERED: 0/6

A //Are CNC/PLC and OT assets isolated in dedicated VLANs separate from corporate IT?
B //Do you maintain a live inventory of all IoT/OT firmware versions?
C //Are default vendor credentials disabled across all industrial routers and gateways?
D //Is remote vendor maintenance restricted via MFA + jump host (no direct exposed ports)?
E //Do you run automated TLS/certificate and vulnerability checks on connected endpoints?
F //Do you have a tested 24-hour incident reporting workflow compliant with EU NIS2?

Send Full Remediation PDF & Audit Scope

Submit your work email with the current score and answers for a remediation summary and proposed audit scope.

CONFIDENTIAL HANDLING // NO MARKETING LISTS

CONFIDENTIAL ENGAGEMENT // DIRECT AUDIT INTAKE

Request an Industrial OT & NIS2 Audit Consultation

Describe your operational environment and audit objective. We will respond with a proposed test scope and a confidential scoping discussion.

Confidential handling. No marketing lists or third-party sharing.

NO PRODUCTION CHANGES WITHOUT APPROVALSTRICT CONFIDENTIALITY